  • Number of Positions: 3
  • Maximum Amperage: 100 A
  • All returns accepted: Returns Accepted
  • MPN: Does Not Apply
  • Color: Multicolor
  • Suitable For: Wall
  • Country/Region of Manufacture: China
  • Operation Method: On/Off
  • Type: Changeover Switch
  • Refund will be given as: Money Back
  • Material: ABS/Plastic
  • Restocking Fee: No
  • Brand: GEYA
  • Return shipping will be paid by: Seller
  • Custom Bundle: No
  • Break Time: Instantaneous
  • Item must be returned within: 30 Days
  • Current Type: AC
  • Voltage: 187-253V
  • Model: W2R-ATS
  • Application: Power Source Transfer
  • Mounting Style: Deep Box
  • Condition: New
  • Features: Automatic Switch

    Description

    Store Categories
    Store Categories
    Time Relay
    On/Off Delay Time Relay
    Multi Function Time Relay
    On/Off Repeat Cycler
    Delay On Star/Delta
    Delay Off Without Supply Vol
    Double Delay Time Relay
    Staircase Switch
    Monitoring Relay
    Single Phase Voltage Relay
    3 Phase Voltage Relay
    Current Monitoring Relay
    Level Control Relay
    Temperature Control Relay
    Light Control Relay
    Memory&Latching Relay
    Intermediate&Auxiliary Relay
    Solid Relay
    Electromagnetic relay
    Voltage protector
    Automatic Transfer Switch
    PV Soler <-> City Power
    Grid Power <-> AC Generator
    Circuit Breaker
    AC MCB
    DC MCB
    AC type ELCB/RCD
    AC-S type ELCB/RCD
    A type ELCB/RCD
    B type ELCB/RCD
    ELCB recloser
    RCBO
    Isolator-Main Switch
    Surge Protection Device
    AC SPD
    DC SPD
    AC Contactor
    Automatic Household Contactor
    Manual Household Contactor
    Industrial Contactor
    Relay Module PLC
    Interface Relay Module (T73)
    1NO1NC plug-in relay module
    OMRON 1NO1NC Plug-in Type
    OMRON 1NO1NC with Fuse
    OMRON 2NO2NC Plug-in Type
    Slim Relay Module PLC 6.2mm
    Current Transformer
    Switch/Sensor
    Photocell Switch
    Proximity Switch
    Digtal Timer Switch
    Solar Storage system
    Distribution Box
    Junction Box
    Plastic Distribution Box
    Electrical accessories
    Other
    GEYA Dual Power Automatic Transfer Switch( Grid - AC Generator)
    Product Description
    Application
    Residence,and in various occasions where continuous power failure is not allowed.
    Function
    Auto mode
    :
    Common power supply must be City Grid Power.  Backup power must be AC genarator.
    When there is only one power supply is working, the product will automatically switch to that power supply. When the common power supply and the backup power supply are supplied at the same time, the common power supply is used Preferentially.
    (Attention: in automatic mode, forcibly rotating the power switch handle will cause damage to the transfer switch)
    Manual mode
    : Power supply should be transfered manually by rotating the handle.
    How to Choo
    se Model
    Split Phase Voltage
    (Live line-Neutral line)
    Line Voltage
    (Live line - Live line)
    Power Systems
    Product you should choose
    110V
    -
    1 Live line + 1 Neutral live
    W2R-2P-63A-110V
    220V
    2 Live line + 1 Neutral live
    W2R-3P-63A-110V
    3 Live line
    3 Live line+ 1 Neutral line
    W2R-4P-63A-110V
    220V
    -
    1 Live line + 1 Neutral live
    W2R-2P-100A-220V(US)
    W2R-2P-100A-220V(CHINA)
    400V
    2 Live line + 1 Neutral live
    W2R-3P-100A-220V(US)
    W2R-3P-100A-220V(CHINA)
    3 Live line
    3 Live line+ 1 Neutral line
    W2R-4P-100A-220V(US)
    W2R-4P-100A-220V(CHINA)
    T
    echnical Parameters
    Item No.
    W2R
    Rated current
    100A
    Rated insulation voltage
    AC690V
    Rated cont
    ro
    l vo
    lta
    g
    e
    AC400V
    (
    -15%
    ~+10%
    );
    50
    ~
    60Hz
    Signal terminal
    rate
    d voltage
    AC220V
    Grade
    PC Level
    : able to male and withstand, not to break short-circuit current
    Use category
    AC-33iB
    Rated impulse withstand voltage
    8KV
    L
    ife
    Electrical:2000times; Mechanical: 5000times
    Rated limited short-circuit current Iq
    50KA
    SCPD (FUSES )
    RT16-00-63A
    Contact transfer tim
    e
    <50ms
    Operating transfer time
    <50ms
    Return transfer time
    <50ms
    Off-time
    <50ms
    Installation
    Din rail mounting
    Distribution box mounting ( buying link: click
    HERE
    )
    Packing List
    1 PCS automatic transfer switch and manual book
    Q&A
    1. Common power supply must be City Grid Power.  Backup power must be AC genarator,
    NO INVERTER
    !
    2. In auto mode, signal terminal AR&AN and BR&BN must be wired to common power supply and backup supply. Or product can not work!
    3. Suggesting add over&under voltage protector to circuit protect product from being burnt due to under-voltage or over-voltage.
    buying link, click
    HERE
    .
    4.
    How to leting product transfer to the backup power X minutes after AC generator starts?
    Adding one delay on time relay to your circuit.  Buying link: please click
    HERE
    .
    5. Do you have plastic distribution box suitable for this item?  Click
    HERE
    Payment Policy
    Shipping Policy
    Returns & Refund Policy
    About us
    Payment Policy
    We only accept pay
    ment
    via
    Paypal at
    prese
    nt.
    If you wan
    t to pay by
    o
    t
    h
    er
    method, please contact me.
    Shipping Policy
    We will process your order within 1 business day upon payment except holidays and weekends.
    Once I update
    t
    racking number, orde
    r
    s can not be canceled.
    Economy shipping:
    all economy shipping parcels
    d
    o
    not
    com
    e
    with tr
    ack
    ing information
    or only provide tracking information when parcels are in China. If you haven't recieved your parcels after wait a long time, please contact your local post office to check your parcel by providing your recipient's name and mobile phone number.
    Standard shipping:
    standard shipping parcels provide whole tracking information.
    Suggested!
    Expedited shipping:
    If you need expedited shipping service, please contact me.
    Returns & Refund Policy
    Please read the item description and check the pictures carefully before making orders. Return or refund is available if:
    1. The item was damaged in transit.
    2. Product quality problem.
    When you submit a return or refund application, please
    1. Provide
    a d
    etailed prob
    lem descriptio
    n and photos
    so that we can deal with it as soon as possible.
    2. Please
    o
    bey
    my
    requirment
    s
    a
    bou
    t
    pa
    c
    king of
    return goo
    d
    s
    .
    After warehouse staff recieve and check your parcel is ok, then I will refund you.
    About us
    Zhejiang Geya Electrical Co., Ltd
    In the past 10 years, Geya has been focusing in low voltage electrical and automation control items research, development and production. We have more than ten years of production experience and have CE, CB and other international certifications. Customization service is also provide.
    Website: www.geya.net
    Copyright © 2018 Dianxiaomi